Used to transport the continuous sample drawn
from the stack to the CEMS Analyzers. The heated
sample line is electrically heat traced and
insulated to maintain a sample stream
temperature above the dew point. Temperature
rating of 350°F at 55°F ambient is typical.
Temperature controller is required (call PACE
for quote on controller). Unheated tube for
delivery of calibration gases to stack for
calibration purposes is also included.
Additional tube for sample filter blowback or
spare is also included.
(Please specify length required.)
The sample line meets the following
specifications:
- Sample
Tubing Material: PFA Teflon
- Sample
Tubing Dimensions: (2) 3/8" x .062"
- Cal Gas
Tubing Dimensions: 1/4" x .040"
- Maximum
Tubing Temperature: 350°F
- Electrical
Requirements: 11.4 w/Ft. @ 120 VAC
- Outer
Jacket Material: FR-PVC
- Nominal
Jacket Temp: 136 F @ 400°F core & amb =100°F
- Maximum
Length: 260 Feet
-
Thermocouple: K Type T/C
- Messenger
Wires: 6 - 14 GA PVC insulated
Call PACE Sales Team at 1-800-303-4532 for
more information.
Email:
In Stock for Immediate Shipment
|